ESTUDO DA VARIABILIDADE DA COLUNA DE ÁGUA PRECIPITÁVEL (PWC) NO SEMIÁRIDO BRASILEIRO PARA CALIBRAÇÃO DE FOTÔMETRO SOLAR

Autores

  • João Gualberto de Cerqueira Jr Instituto Nacional de Pesquisas Espaciais -Centro Regional do Nordeste Universidade Federal do Rio Grande do Norte
  • José Henrique Fernandez Universidade Federal do Rio Grande do Norte (UFRN) Endereços: Campus Universitário UFRN; Av. Sen. Salgado Filho, 3000 - Lagoa Nova, Natal – RN - 59078-970.
  • Judith Johanna Hoelzemann Universidade Federal do Rio Grande do Norte (UFRN) Endereços: Campus Universitário UFRN; Av. Sen. Salgado Filho, 3000 - Lagoa Nova, Natal – RN - 59078-970.
  • Neusa Maria Paes Leme Universidade Federal do Rio Grande do Norte (UFRN) Endereços: Campus Universitário UFRN; Av. Sen. Salgado Filho, 3000 - Lagoa Nova, Natal – RN - 59078-970.
  • Cristina Tobler Sousa Instituto Nacional de Pesquisas Espaciais – INPE – CRN- (Instituto Nacional de Pesquisas Espaciais, Centro Regional do Nordeste). Endereços: Rua: Carlos Serrano, 2073 – Lagoa Nova, NATAL-RN – 59076-740 – Brasil

DOI:

https://doi.org/10.15628/holos.2014.2065

Resumo

A água está presente na atmosfera na forma de vapor, indo desde o nível do solo até a estratosfera. Como principal componente do ciclo hidrológico, a variação em sua quantidade sobre uma região provoca alterações nas condições climáticas, afetando assim as condições de vida e econômicas da população local. O fotômetro solar permite monitorar a variação dessa coluna de vapor de água, ou coluna de água precipitável (PWC) utilizando a radiação solar na banda de 940 nm, que sofre uma forte absorção ao atravessar a atmosfera. Para a calibração do fotômetro solar desenvolvido nesse trabalho, foi investigado um sítio na região semiárida do estado do Rio Grande do Norte, próximo à cidade de Caicó. Foi aplicado o Método de Langley Modificado (MLM) que é uma variação do Método de Langley. Essa metodologia permite calibrar fotômetro solar em campo aberto, que sob a condição de estabilidade óptica da atmosfera, permite obter-se constantes de calibração com melhores índices de incerteza que em laboratório. Os resultados, durante o período estudado, mostraram que não ocorreu a esperada estabilidade óptica da atmosfera para permitir a calibração do equipamento.

Downloads

Não há dados estatísticos.

Métricas

Carregando Métricas ...

Biografia do Autor

João Gualberto de Cerqueira Jr, Instituto Nacional de Pesquisas Espaciais -Centro Regional do Nordeste Universidade Federal do Rio Grande do Norte

Engenheiro Eletricista - Telecomunicações Tecnologista Sênior - INPE Mestre pela UFRN Doutorando em Ciências Climáticas pela UFRN

Referências

Berk, A., L.S. Bernstein, and D.C. Robertson, MODTRAN: A Moderate Resolution Model for LOWTRAN7, technical report, Geophys. Dir., Phillips Lab., Hanscom Air Force Base, Mass., 1989.

Bokoye, A. I., Royer, A., Santer, R., Calibration of sun radiometric integrated water vapour using GPS meteorology. SPIE International Symposium of Remote Sensing, Barcelona, Spain, 8-12 September,2003.

Bruegge, C.J., J.E. Conel, R.O. Green, J.S. Margolis, R.G. Holm, and G. Toon, Water vapor column abundance retrievals during FIFE, J. Geophys. Res., 97, 18,759-18,768, 1992

Castanho, A. D. A., Propriedades ópticas das partículas de aerossol e uma nova tecnologia para obtenção de profundidade óptica via satélite sobre São Paulo, Tese de Doutorado, Instituto de Física, USP, 2005

Gatebe, C. K., O. Dubovik, O., King, M. D., Sinyuk, A., Simultaneous retrieval of aerosol and surface optical properties from combined airborne- and ground-based direct and diffuse radiometric measurements, Atmos. Chem. Phys., 10, 2777–2794, 2010.

Halthore, R. N., Eck, T. F., Holben, B. N., Markhan, B. L.; Sunphotometric measurements of atmospheric water vapor column abundance in the 940nm band, Journal of Geophysical Research, vol 102, No D4, pages 4343-4352, February 27, 1992.

Harrison, L., Michalsky, J.; Objective algorithms for the retrieval of optical depths from ground-based measurements, APPLIED OPTICS Vol. 33, No. 22, pp 5126-5132, 1 August 1994.

Ingold, T., B. Schmid, C. Mätzler, P. Demoulin, and N. Kämpfer,: Modeled and empirical approaches for retrieving columnar water vapor from solar transmittance measurements in the 0.72, 0.82, and 0.94 m absorption bands. J. Geophys. Res., 105 (D19), 24 327–24 344, 2000.

Kaufman, Y.J.; Fraser, R. S.; Light extinction by aerosols during summer pollution.; J. Climate Appl. Meteor.; V.22, 1694-1706, October,1983.

Kneizys, F.X., Shettle, E.P., Chetwynd, J.H., Abreu, L.W., Anderson, G.P., Gallery, W.0, Selby, J.E.A., Clough, S.A.., Users Guide to LOWTRAN 7, AFGL-TR-88-O 177, 1988.

Liou, K. N., An Introduction to Atmospheric Radiation, Academic Press, Second Edition, 579p, 2002.

Liu, C., Li, Y., Gao, W., Shi, R., Bai, k.,; Retrieval of columnar water vapor using measurements over northern China, Journal of Applied Remote Sensing Vol. 5, 2011.

Michalsky, J. J.; Liljegren, J. C.; Harrison, L. C.; A comparison of Sun photometer derivations of total column water vapor and ozone to standard measures of same at the Suthern Great Plains Atmospheric Radiation Measurement site., Journal of Geophysical Research, vol. 100, N0. D12, pages 25,995 – 26,003, Dec 20, 1995.

Mims, F. M., III,: An inexpensive and stable LED Sun photometer for measuring the water vapor column over South Texas from 1990 to 2001. Geophys. Res. Lett., 29, 1642, doi:10.1029/ 2002GL014776, 2002.

Porter, J. N.; Miller, M; Pietras, C., and Motell, C.: Ship-based Sun photometer measurements using Microtops Sun photometers, J. Atmos. Ocean. Tech., 18, 765–774, 2001.

Randall, D.A., R.A. Wood, S. Bony, R. Colman, T. Fichefet, J. Fyfe, V. Kattsov, A. Pitman, J. Shukla, J. Srinivasan, R.J. Stouffer, A. Sumi and K.E. Taylor: Climate Models and Their Evaluation. In: Climate Change 2007: The Physical Science Basis. Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change, 2007.

Reagan, J. A., Thome, K., Herman, B., Gall, R., Water vapor measurement in 0.94micro absorption band: Calibration, measurements, and data applications. Proc. International Geoscience and Remote Sensing Symp.’87 Symposium, University of Michigan, Ann Arbor, 63-57, (1987)b.

Reagan, J. A.; Thome, K. J.; Herman, B. M.; A Simple Instrument and Technique for Measuring Columnar Water Vapor via Near-IR Differencial Solar Transmission Measurements, IEEE Transactions on Geoscience and Remote Sensing, Vol. 30, NO. 4, July, 1992.

Schmid, B.; Thome, K. J.; Demoulin, P.; Peter, R.; Matzler, C.; Sekler, J.; Comparison of modeled and empirical approaches for retrieving columnar water vapor from solar transmittance measurements in the 0.94 µm region., Journal of Geophysical Research, vol. 101, N0. D5, pages 9345-9358, april, 27 – 1996.

Schmid, B., Michalsky, J. J., Slater, D. W., Barnard, J; C., Halthore, R. N., J. C. Liljegren, J. C., Holben, B. N., Eck,T. F., Livingston, J. M., Russell, P. B.; Comparison of columnar water-vapor measurements from solar transmittance methods., Appl. Opt. 40(12), 1886–1896 ,2001.

Shiobara, M., Spinhirne, J. D., Uchiyama, A., and Asano, S., 1991, Optical depth measurements of aerosol, cloud and water vapor using sun photometers during the FIRE Cirrus IFO II. Journal of Applied Meteorology, 35, 36-46.

Slusser, J., Gibson, J., Biglow, D., Langley Method of Calibrating UV filter Radiometers, Journal of Geophysical Research, vol. 105, pg 4841 – 4849 – February 27 – 2000.

Smirnov, A.; Holben, B. N.; Eck, T. F.; Dubovik, O.; Slutsker, I.; Cloud-Screening and Quality Control Algorithms for the AERONET Database , Remote Sense Invironment, 2000.

Shaw, G. E., Sun Photometry, Bull. Amer. Meteor. Soc., 64:4-11, 1983.

Taha, G., Box, G. P.; Water vapor column abundance retrieval using multispectral radiometer measurements in Sydney, Australia, Australian Met. Magazine 51, 165-172, 2002.

Thomason, L. W., Extinction of near infrared solar radiation as a means for remote determination of atmospheric water vapor. Ph.D. Thesis. University of Arizona, Tucson, Arizona, 122 pp, (1985).

Volz, F.E., Economical multispectral sun photometer for measurements of aerosol extinction from 0.44µm to 1.6µm and precipitable water., Appl. Optics, 13: 1732 – 1733, 1974.

WMO - Guide to Meteorological Instruments and Methods of Observation – WMO No.8 - Seventh edition – 2008.

Downloads

Publicado

27/08/2014

Como Citar

Cerqueira Jr, J. G. de, Fernandez, J. H., Hoelzemann, J. J., Leme, N. M. P., & Sousa, C. T. (2014). ESTUDO DA VARIABILIDADE DA COLUNA DE ÁGUA PRECIPITÁVEL (PWC) NO SEMIÁRIDO BRASILEIRO PARA CALIBRAÇÃO DE FOTÔMETRO SOLAR. HOLOS, 4, 298–316. https://doi.org/10.15628/holos.2014.2065

Edição

Seção

ARTIGOS